SHRP

4859-003-55402257–2009 SPECIFICATIONS

№ РРС-04-11 ООО 356 Equipment Use Permit

 

    QUESTIONNAIRE

 

Intended use

Gas Regulating Cabinets GRC and Gas Regulating Systems GRS are intended for pressure reduction of natural gas from high and medium rate to the required rate, as well as for automatic maintenance its specified parameters, gas purification from solids, automatic gas shutdown in case of emergency rise or relief of output pressure.

 

Cabinets can be equipped with gas flow metering set with temperature and pressure correction, providing fiscal or technological gas flow metering.

Operation conditions

GRC and GRS are designed for operating inside the territories with moderate and boreal climate as well as in the regions with cold climate.

Depending on climatic design GRC can be made in heat-insulated cabinets with various types of heating:

  • gas heating (by automated gas burner units);
  • electric heating of explosion-proof design;
  • water heating (heat carrier lead-in from outside source).

GRC consists of:

shutoff valves, various gas filters, gas pressure regulators with two protection stages, gas flow metering systems,manometers, pressure differential sensors, safety relief valves and other equipment installed in the metal cabin, providing tools protection from unauthorized access and negative impact of climatic factors.

he Plant “Neftegazoborudovanie” produces low-duty GRC based on B-series FRANCEL regulators, designed for gas supply of cottages, offices, apartment buildings and other household facilities. Regulators of other well known qualified manufacturers may be used during the equipment engineering .

There are two variants of GRC design:

  • GRC with one reduction line;
  • GRC with main and redundant reduction lines.

The cabinet has a gas flow meter. On customer's demand gas flow metering systems with electronic correctors by temperature and pressure can be installed.

Technical specifications of SHRP-Series pressure reduction cabinets with B-Series FRANCEL regulators:

Marking Inlet gas pressure, mega pascal (kilogramme-force/cm2) Outlet gas pressure, mega pascal (kilogramme-force/cm2) Maximum capacity, scmh, not less
SHRP-В6-1-U1-SG SHRP-В6-2-U1-SG 0,1-0,6 (1-6) 0,0009-0,04 (0,009-0,4) 6
SHRP-В10-1-U1-SG SHRP-В10-2-U1-SG 10
SHRP-В25-1-U1-SG SHRP-В25-2-U1-SG 25
SHRP-В40-1-U1-SG SHRP-В40-2-U1-SG 40

Technical specifications of SHRP- and GRU-Series pressure reduction cabinets and facilities

SHRP- and GRU-Series pressure reduction cabinets and facilities with operational nad backup reduction lines

Marking Regulator Maximum inlet gas pressure, mega pascal The range of outlet gas pressure adjustment, kilo pascal Maximum capacity, scmh, not less
SHRP(GRU)-01-2 RDNK-50 1,2 02.03.05 720
SHRP(GRU)-01P-2 RDNK-50P 03.05.05 720
SHRP(GRU)-01U-2 RDNK-U 02.05.09 800
SHRP(GRU)-400-2 RDNK-400 0,6 02.05.09 240
SHRP(GRU)-400M-2 RDNK-400M 480
SHRP(GRU)-07-2 RDNK-1000 720
SHRP(GRU)-03М1-2 RDSK-50M-1 1,2 01.10.40 624
SHRP(GRU)-03МЗ-2 RDSK-50M-3 40-100 800
SHRP(GRU)-03BM-2 RDSK-50BM 270-300 960
SHRP(GRU)-11N-2 RDP-50N 0,5-60 6032
SHRP(GRU)-11V-2 RDP-50V 60-600 6032
SHRP(GRU)-13N-2 RDG-50N 01.05.60 5496
SHRP(GRU)-13V-2 RDG-50V 60-600 5496
SHRP(GRU)-15N-2 RDG-80N 01.05.60 11680
SHRP(GRU)-15V-2 RDG-80V 60-600 11680
SHRP(GRU)-16N-2 RDG-150N 01.05.60 25600
SHRP(GRU)-16V-2 RDG-150V 60-600 25600
SHRP(GRU)-21N-2 RDP-100N 0,5-60 24080
SHRP(GRU)-21V-2 RDP-100V 60-600 24080
SHRP(GRU)-50-2 RDBK1-50 01.01.60 5200
SHRP(GRU)-50P-2 RDBK1P-50 30-600 5200
SHRP(GRU)-100-2 RDBK1-100 01.01.60 19907
SHRP(GRU)-100P-2 RDBK1P-100 30-600 19907

SHRP- and GRU-Series gas pressure reduction cabinets and facilities with two reduction lines and different regulators (for middle and low pressure) with two outlet lines (with successively installed regulators)

Marking Regulator Maximum inlet gas pressure, mega pascal The range of outlet gas pressure adjustment, kilo pascal Maximum capacity, scmh, not less
outlet 1 outlet 2 outlet 1 outlet 2
SHRP(GRU)-03BM-04-2P RDSK-50BM RDNK-400 1,2 270-300 02.05.09 960 136
SHRP(GRU)-03BM-05-2P RDSK-50BM RDNK-400M 270-300 02.05.09 960 240
SHRP(GRU)-03BM-07-2P RDSK-50BM RDNK-1000 270-300 02.05.09 960 360
SHRP(GRU)-03BM-02U-2P RDSK-50BM RDNK-U 270-300 02.05.09 960 200
SHRP(GRU)-11NV-2P RDP-50N(V) 60-600 0,5-60 6032 2960
SHRP(GRU)-13NV-2P RDG-50N(V) 60-600 01.05.60 5496 3040
SHRP(GRU)-15NV-2P RDG-80N(V) 60-600 01.05.60 11680 6280
SHRP(GRU)-16NV-2P RDG-150N(V) 60-600 01.05.60 25600 13800
SHRP(GRU)-21NV-2P RDP-100N(V) 60-600 0,5-60 24080 11840
SHRP(GRU)-50-50P-2P RDBK1P-50 RDBK1-50 30-600 01.01.60 5200 2542
SHRP(GRU)-100-100P-2P RDBK1P-100 RDBK1-100 30-600 01.01.60 19907 10720

SHRP- and GRU-Series pressure reduction cabinets and facilities with two reduction lines and different regulators (for middle and low pressure) with two outlet lines and parallel regulators

Marking Regulator Maximum inlet gas pressure, mega pascal The range of outlet gas pressure adjustment, kilo pascal Maximum capacity, scmh, not less
outlet 1 outlet 2 outlet 1 outlet 2
SHRP(GRU)-03BM-04-2 RDSK-50BM RDNK-400 0,6 270-300 02.05.09 600 240
SHRP(GRU)-03M3-04-2 RDSK-50M-3 RDNK-400 40-100 02.05.09 480 240
SHRP(GRU)-03BM-05-2 RDSK-50BM RDNK-400M 270-300 02.05.09 600 480
SHRP(GRU)-03MЗ-05-2 RDSK-50M-3 RDNK-400M 40-100 02.05.09 480 480
SHRP(GRU)-03BM-02U-2 RDSK-50BM RDNK-U 1,2 270-300 02.05.09 960 800
SHRP(GRU)-03MЗ-02U-2 RDSK-50M-3 RDNK-U 40-100 02.05.09 800 800
SHRP(GRU)-11NV-2 RDP-50N(V) 0,5-60 60-600 6032 6032
SHRP(GRU)-13NV-2 RDG-50N(V) 01.05.60 60-600 5496 5496
SHRP(GRU)-15NV-2 RDG-80N(V) 01.05.60 60-600 11680 11680
SHRP(GRU)-16NV-2 RDG-150N(V) 01.05.60 60-600 25600 25600
SHRP(GRU)-21NV-2 RDP-100N(V) 0,5-60 60-600 24080 24080
SHRP(GRU)-50-50P-2 RDBK1-50 RDBK1P-50 01.01.60 30-600 5200 5200
SHRP(GRU)-100-100P-2 RDBK1-100 RDBK1P-100 01.01.60 30-600 19907 19907

 

Запрос стоимости оборудования